In-flight calibration of the ROSAT HRI ultraviolet sensitivity
2000
Comparing measured and estimated count rates of a few selected sample stars, we confirm the validity and provide the in-flight calibration of the ROSAT HRI UV/visible effective area model in Zombeck et al. The count rate estimates for Betelgeuse derived with this model are in agreement with the measured HRI upper limit. This result is also confirmed in an erratum by Berghöfer et al. aimed at revising their previous calculation, which was overestimated by more than 2 orders of magnitude. Adopting this ROSAT HRI UV/visible effective area model and measured UV/visible spectra of a set of sample stars covering the range of Teff 3000-40,000 K, we have built the calibration curves to estimate UV/…
The European Photon Imaging Camera on XMM-Newton: The MOS Cameras
2000
The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record the images and spectra of celestial X-ray sources focused by the three X-ray mirrors. There is one camera at the focus of each mirror; two of the cameras contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a circular field of view of 30 arcmin diameter in each case. The CCDs were specially developed for EPIC, and combine high quality imaging with spectral resolution close to the Fano limit. A filter wheel carrying three kinds of X-ray transparent light blocking filter, a fully closed, and a fully open position, is fitted to each EPIC instrument. The CCDs are cooled passively and are under full clos…
JEM–X inflight performance
2003
We summarize the inflight performance of JEM-X, the X-ray monitor on the INTEGRAL mission during the initial ten months of operations. The JEM-X instruments have now been tuned to stable operational conditions. The performance is found to be close to the pre-launch expectations. The ground calibrations and the inflight calibration data permit to determine the instruments characteristics to fully support the scientific data analysis. Reglero Velasco, Victor, Victor.Reglero@uv.es ; Martinez Nuñez, Silvia, Silvia.Martinez@uv.es
JEM–X: The X-ray monitor aboard INTEGRAL
2003
The JEM-X monitor provides X-ray spectra and imaging with arcminute angular resolution in the 3 to 35 keV band. The good angular resolution and the low energy response of JEM-X plays an important role in the identification of gamma ray sources and in the analysis and scientific interpretation of the combined X-ray and gamma ray data. JEM-X is a coded aperture instrument consisting of two identical, coaligned telescopes. Each of the detectors has a sensitive area of 500 cm 2 , and views the sky through its own coded aperture mask. The two coded masks are inverted with respect to each other and provides an angular resolution of 3 0 across an eective field of view of about 10 diameter.
INTEGRAL/SPI ground calibration
2003
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.